Home / Services / Materials Testing / Fort Worth, TX

Fort Worth, Texas

Construction Materials Testing in Fort Worth, TX

Concrete, soil, and aggregate testing in Fort Worth, Texas — fresh concrete tests and cylinder breaks, Proctor and nuclear density, gradation, Atterberg limits, and soil corrosivity — by ACI- and NICET-certified technicians, with results reviewed and issued under a documented quality system.

Lead time
Scheduled by phone or proposal; lead time confirmed when the scope is set
Laboratory
Sugar Land, TX laboratory under chain of custody, or a mobile laboratory for large projects
Reporting
Reviewed and issued under a documented quality system; formatted for owner, engineer, and building-official review
Serving
Fort Worth and the surrounding TX area — Dallas, Abilene
Coverage
Texas statewide · 27 regional hubs
Technicians
ACI Grade I · NICET CMT · ICC special inspectors
Call us
(346) 420-5425

Scope

What we test in Fort Worth

Concrete testing services

Fresh concrete sampled and tested at the pour — slump, air content, unit weight, and temperature — with cylinders and beams cast on site and broken in the laboratory on the schedule your specification calls for.

ASTM C172ASTM C143ASTM C231ASTM C173ASTM C138ASTM C1064ASTM C31ASTM C39

Aggregate testing services

Gradation, fines content, specific gravity and absorption, unit weight, abrasion resistance, and stockpile moisture for concrete, base course, and backfill aggregates.

ASTM D75ASTM C136ASTM C117ASTM C127ASTM C128ASTM C29ASTM C131ASTM C566

Soil compaction and density testing

Standard and modified Proctor curves in the laboratory and in-place density by nuclear gauge on every lift, so fill, subgrade, and trench backfill are documented against the specified percent compaction.

ASTM D698ASTM D1557ASTM D558ASTM D4718ASTM D6938

Soil classification and index testing

Sieve and hydrometer gradation, Atterberg limits, moisture content, specific gravity, and USCS classification for earthwork acceptance, select-fill verification, and geotechnical reports.

ASTM D6913ASTM D7928ASTM D1140ASTM D4318ASTM D2216ASTM D854ASTM D2487

Soil corrosivity testing

pH and electrical resistivity of backfill for MSE walls, pipelines, and buried structures, reported against the specification limits for metallic and geosynthetic reinforcement.

ASTM G51ASTM G57ASTM G187

Special inspection (IBC Chapter 17)

ICC-certified special inspectors for reinforced concrete and soils, reporting to the building official alongside the materials test results, so one agency covers both requirements.

Full scope, standards list, and pricing basis: Construction Materials Testing.

Local conditions

Construction materials testing conditions in Fort Worth

Fort Worth is in the middle of one of the fastest-growing construction markets in the country, and the ground beneath that growth demands attention. North Texas soils — predominantly expansive clays — shift with moisture change, putting slab-on-grade, pavement, and foundation performance directly at risk when compaction and classification work is done carelessly or documented poorly. Summer heat routinely compresses concrete placement windows, making fresh concrete testing a time-sensitive field activity rather than a formality. Our construction materials testing services cover the full scope contractors, developers, and engineers of record need: fresh concrete testing and cylinder breaks per ASTM C31 and C39, aggregate gradation and quality testing, Proctor compaction and nuclear density gauge testing, soil classification, and soil corrosivity evaluations. Work in Fort Worth is dispatched through our Dallas regional hub. Technicians are ACI- and NICET-certified, and the laboratory operates under a documented quality system — so the data you receive is prepared for owner, engineer, and agency review.

North Texas soils are dominated by high-plasticity clays that expand and contract with seasonal rainfall and drought cycles, making accurate Proctor curves and in-place density verification critical on virtually every civil and structural project. Fort Worth's hot summers also require field technicians to monitor concrete air, slump, and temperature promptly at point of discharge, as high ambient temperatures accelerate hydration and can quickly push a mix out of specification.

FAQ · Fort Worth

How does the expansive clay soil common around Fort Worth affect what soil testing I need to order?

High-plasticity clays typical of the North Texas region require both classification testing — Atterberg limits per ASTM D4318 and gradation per ASTM D6913 — and moisture-density relationship testing per ASTM D698 or D1557 to establish a valid compaction target. Without accurate baseline curves suited to the actual borrow or subgrade material on your site, in-place nuclear density readings per ASTM D6938 have no reliable reference to check against.

My spec calls for modified Proctor (ASTM D1557) rather than standard. Can you run that in your lab?

Yes. The laboratory performs both standard Proctor per ASTM D698 and modified Proctor per ASTM D1557. If your project specification, geotechnical report, or TxDOT general notes call out a specific method or energy level, provide that reference when you submit samples and the correct procedure will be applied. Mixing the two methods on a project is a common source of compaction disputes, so matching lab method to field spec matters.

Fort Worth summers are brutal. What precautions apply to concrete cylinder sampling in extreme heat?

ACI 305R addresses hot-weather concreting, and ASTM C31 requires that freshly cast cylinders be stored in an initial curing environment between 60°F and 80°F for the first 24 hours. In Fort Worth summer conditions, that often means insulated curing boxes in shaded or conditioned areas on site. Our technicians verify and document initial curing conditions; failure to meet ASTM C31 initial curing requirements can invalidate 28-day break results and create compliance problems.

How fast can a technician be on site in Fort Worth?

Fort Worth work is dispatched through our Dallas, TX regional hub. Scheduled visits are set up by phone at (346) 420-5425; multi-day placements and full-time project assignments are scheduled through a proposal request.

Which office covers materials testing in Fort Worth, TX?

Field work in Fort Worth is dispatched through the Dallas, TX regional hub, about 31 miles away. Laboratory testing is performed in Sugar Land, TX under chain of custody, or in a mobile laboratory mobilized to large Fort Worth projects.

Are the technicians you send to Fort Worth certified?

Yes. Concrete technicians hold ACI Concrete Field Testing Technician Grade I; soils and laboratory technicians hold NICET Construction Materials Testing certifications; special inspection is performed by ICC-certified special inspectors. Where Texas agencies or owners require state-specific certifications, those are confirmed in the proposal.

Hiring: we staff this work locally. Field technician openings in Fort Worth · all positions.

Scheduling & proposals

Need construction materials testing in Fort Worth?

Call to schedule a technician, or send project documents for a written proposal.

Talk to us

Questions about a project? Send a note.

Nothing here is required — leave a phone number or an email and we'll get back to you. For a written scope, the proposal request form takes plans and specs.

Or call (346) 420-5425 · info@constructionmaterialtesting.com