ASTM D2487: Classification of Soils for Engineering Purposes (Unified Soil Classification System)

The USCS group symbol and name — CL, SM, GP-GM, and so on — assigned from gradation and Atterberg results, which is how specifications, geotechnical reports, and fill acceptance criteria describe a soil.

DesignationASTM D2487
SettingLaboratory
Service lineConstruction Materials Testing

Testing is performed to the current edition of ASTM D2487 referenced by your project specification. This page is a plain-language overview, not a substitute for the published standard.

Related methods

ASTM D421ASTM D422ASTM D558ASTM D698ASTM D854ASTM D1140ASTM D1557ASTM D2216

What ASTM D2487 does

ASTM D2487 is the Unified Soil Classification System. It is not a test; it is the set of rules that takes the results of a gradation and the Atterberg limits and assigns a two-letter group symbol and a group name: CL for lean clay, SM for silty sand, GW for well-graded gravel, CH for fat clay, and so on. That symbol is the shorthand every geotechnical report, boring log, and earthwork specification uses to describe a soil.

When a specification says fill shall be classified as GW, GP, SW, SP, GM, or SM, or requires a CL with a plasticity index under 20, this standard is the reference for what those letters mean.

How classification works, step by step

The fines content from ASTM D6913 or D1140 splits the soil into coarse-grained, less than 50 percent passing the No. 200, or fine-grained. Coarse-grained soils are further split by the gravel-to-sand ratio and by gradation coefficients into well-graded or poorly graded, with fines modifiers if the fines exceed 5 percent. Fine-grained soils are classified from the liquid limit and plasticity index by plotting them on the plasticity chart above or below the A-line, which separates clays from silts. Organic content and highly organic soils have their own categories.

What the classification means

The symbol carries engineering meaning. Well-graded coarse soils compact densely and drain; poorly graded ones do not lock up as well. Silty fines are moisture sensitive and pump under construction traffic. Fat clays, CH, are the expansive soils that heave slabs and foundations across the Gulf Coast and much of the South. A classification alone does not design a foundation, but it tells an engineer what to expect and it tells a contractor whether a borrow source is acceptable.

How we help with ASTM D2487 classification

Every gradation and Atterberg set our laboratory runs on a soil is reported with its USCS classification, so fill approval, subgrade evaluation, and geotechnical correlation can proceed from the same report.

FAQ

Common questions about ASTM D2487

What is the difference between D2487 and D2488?

D2488 is the visual-manual procedure used in the field and on boring logs to estimate the classification by hand. D2487 is the laboratory classification from measured test results. A report should say which was used.

Is USCS the same as AASHTO classification?

No. AASHTO M 145 is a separate system, A-1 through A-7, used by highway agencies. Many DOT specifications use AASHTO groups; building and geotechnical work generally uses USCS.

What does ASTM D2487 cover?

ASTM D2487, Classification of Soils for Engineering Purposes (Unified Soil Classification System). The USCS group symbol and name — CL, SM, GP-GM, and so on — assigned from gradation and Atterberg results, which is how specifications, geotechnical reports, and fill acceptance criteria describe a soil.

Is ASTM D2487 a field test or a laboratory test?

Laboratory. ASTM D2487 is performed in the Sugar Land, Texas laboratory on samples or specimens delivered under chain of custody, or in a mobile laboratory mobilized to large projects.

Which certification qualifies a technician to run ASTM D2487?

NICET Construction Materials Testing (Soils) work elements cover ASTM D2487. Technicians running it are trained and checked on this method under the laboratory quality system, with the training record on file.

Which tests are usually run with ASTM D2487?

ASTM D421 (Dry Soil Sample Preparation), ASTM D422 (Soil Particle-Size Analysis), ASTM D558 (Soil-Cement Moisture-Density), ASTM D698 (Standard Proctor). A project specification usually calls for them together, and one technician visit or one laboratory sample covers the set.

How do I schedule ASTM D2487 testing?

Call (346) 420-5425 for dispatch, or send the specification sections and quantities through the proposal request form for a written scope. Same-day or next-morning scheduling is typical in the Houston metro; other metros are scheduled through the nearest regional hub.

Scheduling & proposals

Need ASTM D2487 testing?

Call to schedule a technician, or send project documents for a written proposal.

Talk to us

Questions about a project? Send a note.

Nothing here is required — leave a phone number or an email and we'll get back to you. For a written scope, the proposal request form takes plans and specs.

Or call (346) 420-5425 · info@constructionmaterialtesting.com